Cruise name: ______________________
Date:_____________________
Is USB disk mounted? _____________________
To mount, use "mount /mnt/UHDAS";
To check, use "df; ls /mnt/UHDAS" and check that
DO THIS AS USER "adcp"; YOU DO NOT NEED
TO BE ROOT.
In the OS38 Instrument Setup table, the first column contains the deep
water (> 500 m) setup defaults and the second column contains the
shallow water setup. The second column shows the bottom track values.
The difference between the two is that when Bottom
Track is on, turn off the OS38NB. When Bottom Track is off, turn on the
OS38NB. Usually, for most of the cruise, Bottom Track will be off. Fill
in the values used at the start of the cruise. For the WH300, BT is
just a toggle, turn ON when water depth is < 100 m.
|
|
Did OS start pinging OK? __________ (i.e., no "instrument is hopelessly confused" message?) (must cycle OS38 deck unit power if this happens) |
Did WH start pinging OK? __________ |